{"product_id":"shopcorp-3-pole-120a-fla-definite-purpose-normally-open-contactor-208-240v-coil-ul-recognized","title":"Shopcorp 3 Pole 120A FLA Definite Purpose Normally Open Contactor, 208\/240V Coil, UL Recognized","description":"\u003ch2 data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003e120 FLA 3 Pole Definite Purpose Contactor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eShopcorp SHDY3XU12JS Definite Purpose Contactor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a heavy-duty \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3 pole normally open contactor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed for compatible HVAC systems, refrigeration equipment, air conditioning compressors, heat pumps, pumps, industrial motors, and electrical control panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120 FLA motor loads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e150A resistive loads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this contactor supports high-current AC switching in properly matched equipment and control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor is designed for systems up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e600VAC maximum\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208\/240VAC, 50\/60Hz coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e208\/240VAC Control Coil\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor operates from a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208\/240VAC coil at 50\/60Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe coil connects through \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eA1 and A2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the three normally open main power contacts switch the connected three-pole load.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe control voltage must match the equipment's available control circuit voltage for proper operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e120 FLA Motor and 150A Resistive Ratings\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe SHDY3XU12JS is rated:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMotor Load:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 120 FLA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eResistive Load:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 150A\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 600VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eLocked rotor ratings include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e120VAC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 720A LRA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e240VAC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 720A LRA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e480VAC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 600A LRA\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e600VAC:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 480A LRA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor should always be selected according to actual motor voltage, horsepower, full-load current, locked rotor current, and application requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e3 Pole Normally Open Configuration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor features three normally open main power poles:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eL1 → T1\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eL2 → T2\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eL3 → T3\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the coil is energized, all three main contacts close simultaneously.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the coil is de-energized, the contacts return to their normally open state.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eDesigned for HVAC and Refrigeration Equipment\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe definite purpose design makes this contactor suitable for properly matched applications such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAir conditioning systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHVAC equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHermetic refrigeration compressors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat pumps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePumps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial motors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRefrigeration equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial and industrial equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eUL Recognized Component\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe SHDY3XU12JS is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL Recognized Component\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUL File:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e E246810\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eA2L Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LZGH2\/8\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is intended for integration into properly designed HVAC, refrigeration, motor-control, and electrical equipment according to applicable installation and equipment requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePanel Mount Installation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epanel mounting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using the mounting holes in the base.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApproximate overall dimensions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 134 mm \/ 5.3 in\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eWidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 86 mm \/ 3.4 in\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eDepth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 111 mm \/ 4.4 in\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMounting hole spacing is approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eVertical:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 113 mm \/ 4.4 in\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eHorizontal:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 64 mm \/ 2.5 in\u003c\/span\u003e\u003c\/p\u003e","brand":"Shopcorp","offers":[{"title":"Default Title","offer_id":68440388337968,"sku":"B0HQ78DCQ6","price":315.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0292\/8823\/5107\/files\/DP3Pole120amp240VNO-Main.jpg?v=1794596012","url":"https:\/\/contactordepot.com\/products\/shopcorp-3-pole-120a-fla-definite-purpose-normally-open-contactor-208-240v-coil-ul-recognized","provider":"ContactorDepot.com","version":"1.0","type":"link"}