{"product_id":"shopcorp-2-pole-63a-no-contactor-120v-ac-dc-coil-for-hvac-lighting-din-rail-ul-recognized","title":"Shopcorp 2 Pole 63A NO Contactor, 120V AC\/DC Coil for HVAC \u0026 Lighting, DIN Rail | UL Recognized","description":"\u003ch2\u003e\u003cspan\u003e2 Pole 63A Modular Contactor with 120V AC\/DC Coil\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eShopcorp BMC7-63U 2 Pole Contactor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHVAC, lighting, automation, control panel, and electrical switching applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requiring a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120V AC\/DC control coil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts compact modular design features \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo normally open main contacts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and supports installation in distribution boxes, HVAC controls, lighting panels, automation systems, and other properly rated electrical equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e63A for AC-1 applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e25A for AC-3 applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the contactor supports properly matched resistive, slightly inductive, and motor-control loads. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e250V AC rated working voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, 120V AC\/DC coil, and compact DIN rail format make it a practical option for low-voltage control systems where reliable two-pole switching is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e120V AC\/DC Coil for Control Circuits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor operates through \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eA1 and A2 coil terminals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120V AC or DC control signal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen the coil is energized, both normally open main contacts close simultaneously, allowing the connected circuit to be switched from a compatible control source.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA front \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estatus indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick visual reference of the contactor operating state.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e63A AC-1 and 25A AC-3 Ratings\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe BMC7-63U is rated for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAC-1:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 63A\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eAC-3:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 25A\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eRated working voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 250V AC\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eImpulse withstand voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4kV\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eShort-circuit rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5kA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e63A AC-1 rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies to resistive or slightly inductive loads such as properly matched heating and lighting circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e25A AC-3 rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies to properly matched motor-control applications, including compatible HVAC equipment, fans, pumps, and similar inductive loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlways select the contactor according to the actual utilization category, operating voltage, load characteristics, and connected equipment requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e2 Pole Normally Open Configuration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe contactor features \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo normally open main contacts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1–2\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003e3–4\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBoth poles operate together when the 120V coil is energized, making the unit suitable for compatible two-line switching applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e35 mm DIN Rail Installation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe compact modular housing is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 mm DIN rail mounting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting installation inside compatible:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHVAC control panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLighting control panels\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDistribution boxes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomation cabinets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectrical enclosures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial control systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eApproximate dimensions are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e36 mm wide × 86 mm high × 68 mm deep\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eUL Recognized Component\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe BMC7-63U is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL Recognized Component\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is marked for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUL 60947-1\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eUL 60947-4-1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUL File:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e E539285\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is intended for integration into properly designed electrical equipment and control systems in accordance with applicable installation requirements and electrical codes.\u003c\/span\u003e\u003c\/p\u003e","brand":"Shopcorp","offers":[{"title":"Default Title","offer_id":68146953388336,"sku":"B0HN8FC78P","price":40.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0292\/8823\/5107\/files\/2pole63Amp120VNOUL-Main.jpg?v=1792608955","url":"https:\/\/contactordepot.com\/products\/shopcorp-2-pole-63a-no-contactor-120v-ac-dc-coil-for-hvac-lighting-din-rail-ul-recognized","provider":"ContactorDepot.com","version":"1.0","type":"link"}